2-120 SmartSwitch ATM Switch Reference Manual
LECSTLVParam
LECSTLVParam
Use LECSTLVParam to remove a TLV parameter from a TLV set on the LECS.
Operators
delete
Parameters
Descriptions
Examples
The
show lecstlvset
example is used here to show how
delete lecstlvparam
works. Observe that [2] in
show
lecstlvset
is [Max Unknown Frame Time]. That is why [Max Unknown Frame Time] appears in
delete
lecstlvparam
when “2” is entered at the [TLVIndex] prompt.
Input Parameter
Description
Value/Field Size
Default
[TLVSetNumber]
Identifier of a TLV parameter set on the LECS.
1-32767
1
[TLVIndex]
Identifier of a specific TLV in the TLV set.
1-15
1
Output Parameter
Description
[TlvIndex]
Number that identifies the specific TLV parameter in the TLV set.
[TLVDescription]
Description of the TLV parameter.
[Value]
Value of the TLV parameter.
Operator
Parameters/Permissions
Description
delete
lecstlvparam
[TLVSetNumber] <tlvsetnumber>
[TLVIndex] <tlvindex>
Administrator
Removes a TLV parameter from a TLV set on the LECS.
Use
show lecstlvset
before entering this command, so
you know the index number of the TLV parameter you want
to delete.