Model 512 Instruction Manual
Page 48
EXAMPLE: Wire List Table Display
W 0001
100 200 RED_WIRE
W
=
Denotes Wire List Table,
0001
=
Sequence number one,
100
=
The FROM point,
200
=
The TO point.
RED_WIRE = Circuit
Label
If no FROM or TO point has been assigned to the sequence number, the FROM and TO display
areas will be blank.
User Notation Table - U
The User Notation Table allows assignment of user notations of 8-character alphanumeric strings
to point numbers. When user notations are assigned to point numbers, all displays and printouts
will show the user notation instead of the tester point number.
EXAMPLE: Notation Table Display
U 001 J1-12345
U
=
User Notation Table,
0001
=
Tester point number one,
J1-12345
=
The user notation for this point number.
NOTE
User notations cannot start with a number.