Model 512 Instruction Manual
Page 19
TEST
In Test mode, one complete scan is performed on the circuit under test. If the scanned
configuration compares exactly with the "learned" continuity program in memory, the test is
successful and the display will show "
Passed
." If an error is encountered, the points in error are
displayed, along with an indication of
OPEN
or
SHORT
. If a printer is connected, and it is
desirable to record errors, use ERROR LIST instead of, or after, this procedure. A complete Test
procedure is provided below. Once familiarized, however, the user may refer to Figure 5. To
select and use TEST, proceed as follows:
1. Load program to be used (refer to "Load Program").
2. Install harness to be tested.
3. Press TEST key;
Single Test
will be displayed, and one complete scan will be made.
4. If
Passed
appears at the end of the scan, the test is successful.
5. An
OPEN
or
SHORT
, with the From/To points, will be displayed when an error is
encountered.
6. To continue test beyond the failed points, press TEST again and testing will resume.
7. When testing is finished, disconnect harness.
RESET
The RESET mode is available for terminating any mode currently in operation. Pressing RESET
is required with some modes that display an end message upon completion. When RESET is
pressed, the display will read
Cablescan Model 512 Ready
.
Summary of Contents for 512
Page 1: ...CONTINUITY TESTER MODEL 512 Cablescan ...
Page 87: ...Page 78 Figure 17 Schematic Scanner Board 1 of 3 ...
Page 88: ...Page 79 Figure 17 Schematic Scanner Board 2 of 3 ...
Page 89: ...Page 80 Figure 17 Schematic Scanner Board 3 of 3 ...
Page 90: ...Page 81 Figure 18 Schematic CPU Board 1 of 3 ...
Page 91: ...Page 82 Figure 18 Schematic CPU Board 2 of 3 ...
Page 92: ...Page 83 Figure 18 Schematic CPU Board 3 of 3 ...
Page 93: ...NOTES ...
Page 94: ...NOTES ...
Page 95: ...5900325 Rev I Cablescan ...