70
SYSTEM ANALYSIS
DYNAMIC TESTS
DYNAMIC TESTS
Cylinder Drop Tests
Use the
Evinrude Diagnostics
software
Dynamic
Tests
to momentarily disable one cylinder while
the outboard is running.
•
The Dynamic Ignition test disables the ignition
and fuel injection circuits to a cylinder.
•
The Dynamic Fuel test momentarily disables
one fuel injector circuit.
By dropping one cylinder, RPM and running qual-
ity changes can be compared for each cylinder.
IMPORTANT:
Test the outboard at the RPM
where the problem is occurring. Use the test pro-
cedures to identify inconsistencies in voltages and
cylinder performance. Once a circuit has been
identified as malfunctioning, inspect all related
wiring and connections. Check all voltage inputs
and grounds; and perform resistance tests for all
circuits before replacing any suspect components.
Dynamic Tests
can be used with:
•
A timing light to determine how other cylinders
are affected by one cylinder being “dropped”; or
•
A digital multimeter to check voltage changes
on electrical circuits.
IMPORTANT:
DO NOT misinterpret tests run at
IDLE. The idle speed controller in the
EMM
com-
pensates to maintain a constant IDLE speed. The
Dynamic Tests
screen includes a function to tem-
porarily disable the idle controller.
Fuel Control Adjustment
Use this test is to help identify a cylinder that may
be too rich or too lean. This feature should not be
used by itself to identify a faulty injector.
Evinrude Diagnostics
software allows temporary
adjustments to the fuel flow characteristics of the
injectors. Factory fuel flow settings are restored
when power to the
EMM
is returned to OFF.
Test the outboard at the RPM where the problem
is occurring.
If the outboard run quality improves with a fuel
control adjustment, eliminate other possibilities
before replacing an injector:
•
•
IMPORTANT:
DO NOT misinterpret tests run at
IDLE. The idle speed controller in the
EMM
com-
pensates to maintain a constant IDLE speed.
Inductive Amp Meter Test
Use an inductive amp meter to monitor battery
charging and current flow. Identifying erratic
amperage in a circuit can be used to isolate a
problem component.
Dynamic Test Screen
008141
008148
Summary of Contents for Evinrude E-TEC Series
Page 1: ...Main Menu...
Page 2: ......
Page 146: ...144 OILING SYSTEM OIL RECIRCULATION DIAGRAM OIL RECIRCULATION DIAGRAM 007316...
Page 194: ...192 POWERHEAD POWERHEAD VIEWS Port Rope Start Models Starboard Rope Start Models 008430 008431...
Page 195: ...193 POWERHEAD POWERHEAD VIEWS 10 Front 007809...
Page 196: ...194 POWERHEAD POWERHEAD VIEWS Rear 007810...
Page 197: ...195 POWERHEAD POWERHEAD VIEWS 10 Top 008280...
Page 292: ...S 2...
Page 322: ...I 8 INDEX...
Page 336: ......
Page 338: ......
Page 341: ......
Page 342: ......