49
Air Temperature ABOVE range
LED 3: OFF (Cranking) / ON (Running)
8 seconds
Air temperature > 158° F (70° C).
51
Fuel injector circuit #1 OPEN
LED 2: ON (Running)
8 seconds
Check injector/circuit resistance—2 to 3
Ω
@ 72°F (22°C).
52
Fuel injector circuit #2 OPEN
LED 2: ON (Running)
8 seconds
57
High RPM with low TPS setting
3
3
LED 3: FLASHING
10 seconds
TPS < 5% and RPM > 3000. Engine SHUTDOWN. Will NOT restart until code has been cleared. The problem could be caused by uncontrolled fuel
entering the engine. DO NOT attempt to start the outboard until the problem has been found and repaired.
58
Operating temperature not reached
LED 3: OFF (Cranking) / ON (Running)
9 minutes
Engine temperature < 104° F (40° C) with engine speed < 2300 RPM.
Check thermostat and pressure relief valve.
61
Fuel injector circuit #1 SHORTED
LED 2: ON (Running)
8 seconds
Check injector/circuit resistance—2 to 3
Ω
@ 72°F (22°C).
62
Fuel injector circuit #2 SHORTED
LED 2: ON (Running)
8 seconds
78
Sensor supply voltage fault
3
LED 3: OFF (Cranking) / ON (Running)
10 seconds
Sensor voltage < 4.75 V. Check sensors and related wiring. Check for pinched or chafed wiring.
81
Ignition timing circuit #1 OPEN
LED 2: ON (Running)
10 instances
EMM
counts failed ignition events. Check wiring. Test with known good ignition coil.
82
Ignition timing circuit #2 OPEN
LED 2: ON (Running)
10 instances
91
Fuel pump circuit OPEN
LED 2: ON (Running)
8 seconds
Check pump/circuit resistance—2 to 3
Ω
@ 77°F (25°C).
94
Fuel pump circuit SHORTED
LED 2: ON (Running)
2 seconds
Check pump/circuit resistance—2 to 3
Ω
@ 77°F (25°C).
101 Ignition timing circuit #1 SHORTED
LED 2: ON (Running)
5 events-low speed
2 events-high speed
EMM
counts failed ignition events. Check wiring. Test with known good ignition coil.
102 Ignition timing circuit #2 SHORTED
LED 2: ON (Running)
5 events-low speed
2 events-high speed
117 Critical LOW OIL detected
3 3
LED 4: ON (Running)
6700 Pulses
EMM
counts oil pump pulses after LOW OIL switch closes. Engine limited to 1200 RPM.
Stop outboard and add oil to tank. Warning resets after three oil pump pulses.
120 Oil level sensor OPEN
3
LED 4: ON (Running)
4 seconds
Check switch continuity—open below 1/4 capacity, closed above 1/4 capacity.
NOTE: Always note service codes before clearing codes. Clear stored codes using diagnostic software. Clearing some codes requires turning EMM “OFF” and then “ON” again.
CODE
EMM
CIRCUIT/SENSOR
INTERNAL
SENSOR
S.A.F
.E
SHUT
DOWN
EMM
LED DISPLAY
TIME TO
ACTIVATE
SENSOR: CIRCUIT VOLTAGE / RESISTANCE (
Ω
) / INFORMATION
page 2
Rev 01/10
Summary of Contents for Evinrude E-TEC Series
Page 1: ...Main Menu...
Page 2: ......
Page 146: ...144 OILING SYSTEM OIL RECIRCULATION DIAGRAM OIL RECIRCULATION DIAGRAM 007316...
Page 194: ...192 POWERHEAD POWERHEAD VIEWS Port Rope Start Models Starboard Rope Start Models 008430 008431...
Page 195: ...193 POWERHEAD POWERHEAD VIEWS 10 Front 007809...
Page 196: ...194 POWERHEAD POWERHEAD VIEWS Rear 007810...
Page 197: ...195 POWERHEAD POWERHEAD VIEWS 10 Top 008280...
Page 292: ...S 2...
Page 322: ...I 8 INDEX...
Page 336: ......
Page 338: ......
Page 341: ......
Page 342: ......