270
TRIM AND TILT
ROUTINE INSPECTIONS
ROUTINE INSPECTIONS
General
Check for external signs of fluid leakage. Correct
causes as necessary.
Check the battery and make sure it is in good
operating condition.
Reservoir Fluid
Check reservoir fluid level at least every three
years or 300 operating hours. System capacity is
approximately 15.2 fl. oz. (450 ml).
IMPORTANT:
Use only
Evinrude/Johnson
Bio-
degradable TNT
Fluid to fill the hydraulic system.
Refer to
dure.
Manual Release Valve
Check the manual release valve with a torque
wrench.
IMPORTANT:
Tighten valve to a torque of 45 to
55 in. lbs. (5 to 6 N·m).
Stern Brackets
Inspect the stern brackets for binding.
Tighten starboard tilt tube nut to a torque of 45 to
50 ft. lbs. (61 to 68 N·m).
TROUBLESHOOTING
Use the following guidelines to check a single pis-
ton trim/tilt unit that is not working correctly.
Cylinder Leakdown:
•
Manual release valve seals
•
External leaks
No reverse lock:
•
External leaks
No operation, motor runs:
•
Manual release valve open
•
Fluid level low
•
Pump coupler
•
Hydraulic pump
No tilt down:
•
Manual release valve
•
Fluid level
Slow performance:
•
Manual release valve
•
Fluid level low
•
Mechanical binding
•
Electric motor
•
Hydraulic pump
Unit locked in tilt up:
•
Mechanical binding
•
Hydraulic pump
Summary of Contents for Evinrude E-TEC Series
Page 1: ...Main Menu...
Page 2: ......
Page 146: ...144 OILING SYSTEM OIL RECIRCULATION DIAGRAM OIL RECIRCULATION DIAGRAM 007316...
Page 194: ...192 POWERHEAD POWERHEAD VIEWS Port Rope Start Models Starboard Rope Start Models 008430 008431...
Page 195: ...193 POWERHEAD POWERHEAD VIEWS 10 Front 007809...
Page 196: ...194 POWERHEAD POWERHEAD VIEWS Rear 007810...
Page 197: ...195 POWERHEAD POWERHEAD VIEWS 10 Top 008280...
Page 292: ...S 2...
Page 322: ...I 8 INDEX...
Page 336: ......
Page 338: ......
Page 341: ......
Page 342: ......