75
SYSTEM ANALYSIS
IGNITION OUTPUT TESTS
5
Static Ignition Test
Perform the static ignition test using
Evinrude
Diagnostics
software and an inductive timing light.
IMPORTANT:
Do NOT perform static tests using
Diagnostic Power Supply Tool, P/N 587005, with
internal 9 volt batteries only. This will produce
false results. Refer to
IMPORTANT:
DO NOT use a spark checker
tool. Radio Frequency Interference (RFI) gener-
ated by the arcing current can cause erratic
EMM
operation.
The outboard must NOT be running and the emer-
gency stop switch lanyard must be installed.
Connect timing light pickup to the secondary cir-
cuit (spark plug lead) of the cylinder being tested.
Activate test and observe timing light strobe for
consistent flash.
IMPORTANT:
This test is operating the ignition
coil with 12 V battery power on the system voltage
(55 V) circuit. An inductive probe with low sensitiv-
ity may not be able to detect the signal.
Results:
No spark on one or more cylinders:
•
Inspect or replace spark plugs
•
Refer to
Ignition Control Circuit Tests
•
Refer to
Steady spark on all cylinders:
•
Static Tests Screen
008140
1.
Timing light pick-up
2.
Spark plug lead
007398
1
2
Summary of Contents for Evinrude E-TEC Series
Page 1: ...Main Menu...
Page 2: ......
Page 146: ...144 OILING SYSTEM OIL RECIRCULATION DIAGRAM OIL RECIRCULATION DIAGRAM 007316...
Page 194: ...192 POWERHEAD POWERHEAD VIEWS Port Rope Start Models Starboard Rope Start Models 008430 008431...
Page 195: ...193 POWERHEAD POWERHEAD VIEWS 10 Front 007809...
Page 196: ...194 POWERHEAD POWERHEAD VIEWS Rear 007810...
Page 197: ...195 POWERHEAD POWERHEAD VIEWS 10 Top 008280...
Page 292: ...S 2...
Page 322: ...I 8 INDEX...
Page 336: ......
Page 338: ......
Page 341: ......
Page 342: ......