56
en | Configuring the AutoDome 700 Series
AutoDome 700 Series IP PTZ Camera
F.01U.273.798 | 3.0 | 2012.08
User Manual
Bosch Security Systems, Inc.
2.
Enter new scripts in the
Alarm Task Editor
field or change existing scripts in line with
your requirements.
3.
When you are finished, click the
Set
button to transmit the scripts to the unit. If the
transfer was successful, the message
Script successfully parsed
is displayed over the
text field. If it was not successful, an error message will be displayed with further
information.
4.44
Alarm Rules
The AutoDome 700 Series features an alarm rule engine. In its simplest form, an alarm rule
can define which input(s) activate which output(s). Basically, an alarm rule allows you to
customize an AutoDome 700 Series to automatically respond to different alarm inputs.
To configure an alarm rule specify one input from either a physical connection, a motion
detection trigger, or from a connection to the camera’s Livepage. The physical input
connection can be activated by dry contact devices such as pressure pads, door contacts and
similar devices
Next, specify up to two (2) rule outputs, or the camera’s response to the input. Outputs
include a physical alarm relay, an AUX command, or a preposition scene.
1.
Click the Enabled check box to activate the alarm.
2.
Choose one of the following alarm inputs:
–
Local Input 1: a physical alarm connection.
–
Local Input 2: a physical alarm connection.
–
IVA/: an alarm when IVA or motion detection is activated.
–
Connection: an alarm when an attempt is made to access the camera’s IP address.
3.
Choose one of the following output commands for both Output 1 and Output 2 settings:
–
None: no defined command.
–
Alarm Relay: defines a physical connection from the open collector alarm output.
–
Aux On: defines a standard or custom keyboard ON command.
Refer to
Section 6 User Command Table, page 71
, for a list of valid commands.
Note
: Only commands 1, 8, 18, 20, 43, 60, 80, 86 are supported. Support for the
remaining commands is scheduled for a future release.
–
Aux Off: defines a standard or custom keyboard OFF command.
Refer to
Section 6 User Command Table, page 71
, for a list of valid commands.
Note
: Only commands 1, 8, 18, 20, 43, 60, 80, 86 are supported. Support for the
remaining commands is scheduled for a future release.
–
Shot: defines a preset scene from shot 1-99.
4.
Click Set to save and to activate the alarm rules.
4.45
Advanced Mode: Interfaces
4.46
Alarm Inputs
Select the type of input for each physical alarm. Select from either
N.O.
(Normally Open) or
N.C.
(Normally Closed) and provide an optional name for each input.
4.47
Relay
The AutoDome 700 Series incorporates one (1) open collector alarm output. Use the following
settings to configure the relay.
Summary of Contents for VG5 700 Series
Page 1: ...AutoDome 700 Series IP PTZ Camera VG5 700 Series en User Manual ...
Page 2: ......
Page 81: ......