Problem
Solution
No Network
Connection
–
Check all network connections
–
Ensure that the maximum distance between any two Ethernet connections is
100 m (328 ft) or less.
Refer to the
VG5 AutoDome Installation Manual
for more information.
If O.K., then:
–
If you are behind a firewall, ensure that the Video Transmission mode is set to UDP.
a.
Access the Settings Web page for the IP-enabled device.
b.
Expand the Service Settings link, then click Network.
c.
Select UDP from the Video Transmission drop-down list. Then click Set.