Security Escort
System components/specifications | en
15
Robert Bosch (SEA) Pte Ltd
Training Manual
2017.08 | V2.18.1.0 | DOC
When the transmitter is tested, a special “low battery” message is included in the
transmission to Central Console if the transmitter’s battery is in need of replacing. Every
successful test is recorded in the
Subscriber Database
in the Central Console software and
optionally printed on the hardcopy printer. The
Subscriber Database
contains all of the
information relating to each subscriber, including the date and time of the most recent test
transmission. It is possible to search the
Subscriber Database
for individuals who have not
performed tests for a specified period of time.
2.4
SE3401 asset tracking transmitter
Features
–
Alerts Central Console of Transmitter’s ID and location immediately on alarm.
–
Available post-alarm tracking, alarm map recall, and more.
–
Internal antenna.
–
Two-year battery life.
–
Can be mounted virtually anywhere on virtually anything.
–
Low battery indication at Central Console.
–
Includes mounting plate.
Description
The SE3401 Point Tracking Transmitter contains a unique code which is associated with an
asset at the time the Transmitter is assigned. When an alarm is generated, this code is sent to
the Central Console, which graphically displays the asset’s location on a map along with a
picture of the asset and any other necessary information.
Installation
The SE3401 can be configured to monitor magnetic or dry external contacts. When mounted
with an external magnet, the SE3401 is mounted on the asset and the magnet is mounted on
an opposite surface (such as a wall). When mounted with external contacts, the SE3401 can
be mounted anywhere on the asset and connects to the contact by two wires connected to
the terminals inside the Transmitter and an end-of-line resistor.
Transmitting an Alarm
Depending on the installed options, when an alarm is generated within approximately two
seconds, the sounders in any nearby Receivers could be activated as well as the Strobes and
Sirens connected to nearby Alert Units. The alarm signal is transmitted to the Receivers which
in turn relay the alarm signal to the Transponder and along to the Central Console. The Central
Console graphically displays the Transmitter’s location along with the asset’s description and
a picture of the asset. Also, once an alarm is initiated, the Transmitter commences its Auto-
Tracking feature.
Auto Tracking Feature
Once an alarm has been initiated (such as when the Transmitter has been moved away from
the magnet) the Auto-Tracking feature will begin. The Transmitter will send a signal back to
the Central Console every few seconds updating its location for several minutes. To reset the
Transmitter after an alarm has been initiated, all device conditions (e.g., tamper, loop,
magnet) must be reset to normal.