Dimensions:
52 mm (2.05 in) x 80 mm (3.15 in) x 22 mm (0.89 in)
Power:
Use the included 12 – 48 V DC on barrel connector
Recommended
Cable:
Standard male DB9 to female DB9 serial cable (not included).
4.6.3
Installation and operation notes
–
The Moxa device must be powered at all times. Use the included power adapter.
–
A standard male DB9 to female DB9 serial cable is used to connect the transponder to
the Moxa device.
–
Instructions on setting up the Moxa device is based on the recommended model NPort
5150 (firmware version: 3.4 Build 11080114).
The pinouts of male DB9 serial port of Moxa NPort 5150 are as follows:
Figure 4.8: Moxa NPort 5150 Male DB9
Pin Number
RS-232
RS-422/RS-485
(4W)
RS-485
(2W)
1
DCD
TXD-(A)
--
2
RxD
TXD+(B)
--
3
TxD
RXD+(B)
Data+(B)
4
DTR
RXD-(A)
Data-(A)
5
GND
GND
GND
6
DSR
--
--
7
RTS
--
--
8
CTS
--
--
9
--
--
--
Notice!
Third party user interfaces are subject to change without notice at the sole discretion of the
respective providers but configuration setting shall remains as specified.
Follow the instructions below to set up the NPort 5150 device and use the serial cable to
connect the transponder to the Ethernet network.
1.
Connect NPort 5150 to the Ethernet network.