Security Escort
System wiring | en
51
Robert Bosch (SEA) Pte Ltd
Training Manual
2017.08 | V2.18.1.0 | DOC
6.
Go to
Channel 1
>
Connection
. Select “TCP” from the drop down list of
Protocol
field.
Enter the port number of the transponder in the
Local Port
field. This port number is the
same number as the one that is set for the transponder in the
Transponder Database
of
the Security Escort software.
7.
Click the
[OK]
button to apply the settings.
8.
The connecting cable is a modified male DB9 to male DB25 serial cable. Only 3 wires are
compulsory for the modification of DB9 to DB25 cable as illustrated in the table below.
RS232 Pin Assignment
DB9 Pin Male
DB25 Pin Male
Pin
Pin
2
2
3
3
5
7
Tab. 4.3:
Wiring – Required pins
9.
Connect the male DB9 connector to the transponder and the male DB25 connector to the
Lantronix device.