8.3.9
System status
This dialog shows the status of internal system queues and communications on the serial
ports assigned to transponders.
Figure 8.25: System Status Dialog
Maximum Retry Messages
This value is maximum number of messages in queue to be
sent to all transponders in the system, and were not yet
acknowledged. If displayed in yellow, more than 50% of the
queue was in use at this value.
Maximum Alarm Messages
This value is the maximum number of alarms that the system
processed at its busiest time. If displayed in yellow, more
than 50% of the maximum was in use.
Maximum Trouble Messages
This value is the maximum number of troubles in the queue
yet to be displayed. If displayed in yellow, more than 50% of
the queue was in use.
Max Low Battery Messages
This value is the maximum number of transmitters with low
batteries yet to be displayed. If displayed in yellow, more
than 50% of the queue was in use.
Max Test Strobe Messages
This value is the maximum number of test strobes in use at
one time. If displayed in yellow, more than 50% of the queue
was in use.
Max Man Down Messages
This value is the maximum number of transmitters timing
man down events, at one time. If displayed in yellow, more
than 50% of the queue was in use.
Supervision Monitors
This value is the current number of transmitters being
monitored for supervision transmissions.
Max Spooler Bytes
This value is the maximum number of bytes spooled for the
printer at one time. If displayed in yellow, more than 50% of
the queue was in use.