en | Troubleshooting transponders, points, receivers, and alert units
Security Escort
2017.08 | V2.18.1.0 | DOC
Training Manual
Robert Bosch (SEA) Pte Ltd
Notice!
Area data of the transponders is not supported. Only point data of the transponders is used
for the export and import of “.dat” files.
Data fields in required
order
Excel Column Restrictions
#Transponder ID
A
1-255. This field should contain only numeric
ASCII characters.
Coordinator ID
B
Reserved for future use, this field should contain
only the numeric 0.
Transponder Name
C
This field may be up to 24 characters. This field
may contain any printable ASCII character
except the ‘?’
IP Connected
D
"0 RS232", "1 TCP IP". This field should contain
only numeric ASCII characters.
Coordinator
E
0. Reserved for future use, this field should
contain only the numeric “0”.
IP Address
F
This field is blank if
IP Connected
is 0 (RS232).
This field should contain a valid IP address if
IP
Connected
is 1 (TCP IP).
Port Number
G
This field is blank if
IP Connected
is 0 (RS232).
This field should contain only numeric ASCII
characters, 1-65535.
Comm Port Index
H
This field used only if
IP Connected
is 0
(RS232). “0 A”, “1 B”, “2 C”, “3 D”, “4 E”, “5 F”,
“6 G”, “7 H”, “8 I”, “9 J”, “10 K”, “11 L”
Ignore Communications
Failure
I
This field is 0 if this is not selected. This field is
1 if this is selected. This field should contain
only numeric ASCII characters.
Isolate For Location
J
This field is 0 if this is not selected. This field is
1 if this is selected. This field should contain
only numeric ASCII characters.
Trouble Text
K
This field may be up to 40 characters. This field
may contain any printable ASCII character
except the ‘?’.
Tamper Text
L
This field may be up to 40 characters. This field
may contain any printable ASCII character
except the ‘?’.
Trouble Response
M
This field may be up to 135 characters. This field
may contain any printable ASCII character
except the ‘?’