46/83 ctrlX
SAFETY
| Device type SAFEX-C.12
R911405651, Bosch Rexroth AG, DOK-XSAFE*-SAFEX-C.1XC-IT03-EN-P, Edition 03
9.2.2.2
TCP/IP (in preparation)
Tabelle 28:
Term
Type / Value
Description
Technology TCP/IP
Standard
Ethernet
XF28 IN
Ethernet, RJ45
Connection from the preceding SAFEX-
C.1* device,
Connection to the engineering PC
XF29 OUT
Ethernet, RJ45
Connection to the subsequent SAFEX-
C.1* device,
alternative connection to the engineering
PC
Protocol UDP
TCP
User Data Protocol for SMMC
(Safe Master - Master communication)
Engineering communication
Safety protocol
SMMC over UDP
Safe SMMC cross communication
between SAFEX-C.1* devices (safe
Master - Master communication)
Min. cycle time
4 ms
According to controller cycle
Main task