| Device type SAFEX-C.15
R911405651, Bosch Rexroth AG, DOK-XSAFE*-SAFEX-C.1XC-IT03-EN-P, Edition 03
Tabelle 58:
LED device diagnostics (Lightpipe, PF01)
PF01
Start-up phase,
Device status
Color
Flashing
pattern
Meaning
-
-
Off
No voltage supply
Init,
Self-test,
Stop,
BusInit
Yellow
Flashing
The controller is in the startup
phase or STOP or a
program/firmware download is
being performed.
RunIntern
Yellow
Permanently
illuminated
Local operation of the device
as FSoE master (FSOE slave
user not yet in Run)
Run Green
Flashing
The
controller is functioning
correctly; the application is
running, but has not (yet)
been validated.
Run Green
Permanently
illuminated
The controller is functioning
correctly; the application is
running and validated.
Alarm Red
Flashing
Alarm
(application error) - the
device is in a safe operating
state. Error status and safety
program can be reset.
1)
Error Red
Permanently
illuminated
Fatal error - the device is in a
safe operating state. The error
state can only be reset via
POR.
1)
You can find a description of an alarm reset in the “Programming manual for ctrlX SAFETY SAFEX-C.1* devices with
ctrlX SAFETY Engineering DOK-XSAFE*-SAFEX-C.1XC-PRxx-DE-P