The field Test Transmission Period can take a value ranging or from 1 to 59 if the period is set in
minutes, or from 1 to 24 if the period is set in hours or at a specified time, or from 1 to 12 when the
Twice a Day flag is set on.
Apart from the mode of phone call at a specified time the period of sending Test message is
counted starting at the moment of last transmission of any message (including response messages to the
balance request and SMS control commands) to the relevant cell phone.
In the mode of a phone call on receiving the test notification the subscriber takes a call and this is
a confirmation for the UO-4S that the notification is taken. Then the UO-4S clears the line. The call time
doesn’t exceed two seconds and as a rule is not charged by a communication operator.
If a Test notification is sent in one direction then it will not be transmitted to other
directions.
SMS-notification “Test” can be used only with SMS notification types (User SMS, Egida-2
SMS, Egida-3 SMS)
Dial-up Phone Number
This is a number of the telephone where dial-up is made when an alarm loop with the Phone Call
type is activated. This phone number must be entered in full, including the area code. When a call is
made from this number the UO-4S picks up the handset to broadcast the signal from the microphone.
Permit to Take Off the Receiver
When called from the phone number for dialing, the panel turns on the microphone and speaker
(if they are connected to the corresponding terminals) for the specified listening time in 10 seconds
intervals.
Phone Call Hold
If at the moment of translation the panel is ringed up, the panel doesn’t hang up.