30
Device
•
Operation Mode: This parameter provides selecting the mode of panel operation.
The required operation mode must be obligatory selected prior to proceeding to set-
ting parameters of credentials, zones, and partitions.
•
Use Backup SIM Card: If a second (backup) SIM card is installed into the UO-4S then when a
notification cannot be transmitted over the primary notification channel (poor communication
quality, zero or negative account balance) this one will be transmitted over the backup
communication channel (both cards are equivalent and the panel returns to operation with the
primary card only when transmitting data using the backup card fails or after power-on reset).
•
Extended Character Set: The parameter informs that notifications are transmitted using Unicode
extended character set (the UO-4S starts transmitting SMS in Unicode if the object name or User
SMS contain Cyrillic characters).
•
Transmit SMS with Data: If this parameter is set on then the UO-4S transmits User SMS with the
data, not only with the time.
•
Configuration Read Protection: This parameter can be set on / off when a password against
unauthorized programming of the panel is given. If the parameter is set on then in case of an
attempt to read configuration after 30 seconds since last programming UProg will ask the password.
Figure 13. The Dialog Window to Enter Configuration Password
Configuration Password can be discarded upon panel’s entering the programming
mode without presenting Master Key (on powering the panel up with closed terminals
of the reader). Then panel’s configuration should be read and password should be
changed or discarded.
•
Disable Panel Indication: If this parameter is set on then the panel indicates events neither by
lighting nor by sounding except for GSM LED and reader indication. Indication can be suppressed
only when the tamper switch of the panel is closed.