Also your own encryption key can be generated by the program automatically using the typed
passphrase. For doing so, enter a password in Latin script into the Password field, then confirm it, and
finally save changes by clicking OK. For Egida 3 Central Monitoring Station the same password must
be entered in GPRS settings for this UO-4S to provide decoding of the notifications.
W/o Encryption: If this flag is set on then the UO-4S sends DC09 notifications without
encrypting them. (This parameter is recommended to be set on for networks with low GPRS channel
throughput and high density of events sent from the UO-4S to the CMS (Central Monitoring Station).
If backup channel is not in use then there must be all zeros in the IP Address and Port fields.
Common settings are the following:
•
Connection Establishment Timeout (60 seconds is recommended)
•
Response Waiting Timeout (20 seconds)
•
Transmission Attempts (the minimum recommended value is 2-3 attempts)
•
TEST Transmission Period (60 to 250 seconds); this time must be longer than call setup time
•
Group Number (the number of the group in which GPRS-transmission is included)
Carrier settings, to be set individually for SIM1 and SIM2:
•
Login (the login (account name to access GPRS service of the carrier. For every carrier its
specific login must be used, for example “mts” for the “
МТС
” carrier, “beeline” for the “Bee-
line” carrier, and “megaphone” for the “
Мегафон
” carrier)
•
Password (the password to access GPRS service of the carrier. For every carrier its specific
password must be entered, for example “mts” for the “
МТС
” carrier, “beeline” for the “Bee-
line” carrier, and “megaphone” for the “
Мегафон
” carrier )
Access point name APN (the name of the GPRS/3G gateway for your carrier, for example
“internet.beeline.ru” for “Beeline”, “internet.mts.ru” for “
МТС
:, and “internet.megafone.ru” for
“
Мегафон
”).