38
Enrolling Credentials by means of an iButton Reader
To enroll credential codes by means of an iButton reader, the iButton reader should be connected
to the UO-4S terminals 23, 24, and 25 (see Figure 5).
1.
Load the panel configuration by means of UProg. Go to the Credentials tab. When the Cre-
dential tab has been open the device descriptors start being read from the panel memory au-
tomatically.
2.
Add a new credential descriptor on the Credential tab by clicking
.
3.
Then read the credential code
. If the credential code is read successfully the panel beeps
and a unique code appears in the relevant Credential Code cell.
4.
Next, define the credential rights by ticking the boxes in the cells of the alarm loops which
can be operated by the credential. Then save the credential to the panel memory by
activating the tool
, «Write credentials to the device».
5.
To delete a credential descriptor from the panel memory use the button
.
Setting Local Credentials
Figure 17. Local Credentials
•
Type: The type of the credential. The value of Type can be one of iButton (TM), Operating
Loop (OL), Telephone (T1, T2, T3, T4, T5), or PIN code (PIN).
•
Credential Code: For iButtons their codes are read by means of the iButton reader and for tel-
ephones the code is entered using the keyboard (5 digits).
•
Rights: Operating authorities of the credentials (Arming, Disarming, Arming / Disarming).
•
LP1 – LP4: The numbers of the alarm loops which can be operated by the credentials.