7.8.4 Example of a Correct Topology
7.8.4.1 Control Unit of an lift Out of a Group
From the picture you can see the line structure
and the terminations of the control unit of an lift
out of a group. The car bus is blue and group bus
red. Provided that the stub line to the inverter is
shorter than 3 m, termination can be realised at
the bp 308 as well. Termination on the car is
done by means of a connected absolute encoder
or a DIP switch (DIP 2 set to "on") on the CLK-
03. Termination of the group bus at the end of
the well is normally realised by activating the ter-
mination on the DIP switch of the last CAP-01/02
(DIP 2 set to "on").
63
Fig. 43
Sample of the topology of a single lift .