The control unit made by Firma BÖHNKE + PARTNER comes with:
•
circuit diagrams, unambiguously identified by the serial number
of the control unit (e.g.:
: 93401)
•
Parts lists,
EC type examination certificate and declaration of conformity for
System bp308,
•
Terminal plans,
•
Basic settings,
•
Port assignment plans and general tips concerning the control
system bp308.
Are these documents complete?
Yes □
Have you followed the circuit diagrams that belong to the control
unit
Yes □
Have you paid attention to the safety instructions in section 7.2
'
Interference Suppression and Hints"
and followed them?
Yes
Have you checked that all terminal points are correctly and tightly
connected?
Yes □
Have you turned off the main switch ?
Yes □
Have you connected the voltage test module STM-02 (see section
Fehler: Referenz nicht gefunden)?
Yes □
Check the voltage supply! Have L1, L2, L3, N and PE been properly
connected (clockwise rotating field)?
Yes □
Does the cross section of the conductors correspond to the power
draw of the lift system?
Yes □
If there is a load switch, have you checked whether the admissible
fusible elements are installed as well?
Yes
Is the automatic circuit breaker 1F2 for the control voltage switched
off?
Is the automatic circuit breaker 1F4 for the safety voltage switched
off?
Yes
Yes
Have the power supply lines been correctly fused?
Yes □
If there is a quick activation circuitry available for the brake, have
the protection switches been turned on?
Yes □
The motor protection switch, over-current activator, FI protection
switch, phase monitor etc. installed in the monitoring unit can only
be pre-installed by BÖHNKE + PARTNER. When commissioning the
system, you have to set them to the values suiting the appliances
connected.
Have you set these values?
Yes □
Have all the PE conductors been connected properly?
Yes □
Have you complied with all interference suppression measures and
EMC instructions of the frequency inverter manufacturer?
Yes □
Have you followed the commissioning instructions concerning speed
and drive controls?
Yes □
Has the emergency control unit been switched on?
Yes □
87
Summary of Contents for bp308
Page 14: ...15...
Page 15: ...16 Installation Manual System bp308 Product Certifications...
Page 54: ...55 Fig 31 Interference suppression circuit diagrams...
Page 114: ...Appendix A Menu Navigation bp308 Version 88D2312 29 08 2013 116...
Page 115: ...117...
Page 150: ...152...
Page 154: ......