![Böhnke + Partner bp308 Installation Manual Download Page 127](http://html1.mh-extra.com/html/bohnke-partner/bp308/bp308_installation-manual_2784778127.webp)
| | +- Door times
| | | * Dwell time after light curtain
| | | 1..20 [1] s
| | | * Dwell time after force limit
| | | 1..20 [3] s
| | | * Dwell time after door open button
| | | 1..20 [4] s
| | | * Close doors when idle
| | | off/1..240 [8] s
| | | * Advance warning close idle door
| | | off/1..60 [off] s
| | | * Advance warning open door
| | | off/1..15 [off] s
| | | * Advance warning close door
| | | off/1..15 [off] s
| | | * Door nudge time
| | | off/1..60 [off] s
| | | * Advance warning door nudging
| | | off/1..15 [off] s
| | | * Load time 1
| | | off/1..239/Unlimited [1] min
| | | * Load time 2
| | | off/1..239/Unlimited [1] min
| | | * Enable motion detector after
| | | off/1..10000 [off] ms
| | | * Disable motion detector after
| | | off/1..20000 [off] ms
| | | * Motion detector timeout
| | | off/1..60 [18] s
| | | * Monitoring time door open
| | | off/1..60 [10] s
| | | * Monitoring time door close
| | | off/1..60 [10] s
| | | * Delay for signal close door (66)
| | | off/1..600 [off] s
| | | * Duration signal close door (66)
| | | 1..20 [3] s
| | | * Repeat delay signal close door (66)
| | | off/1..600 [15] s
| | | * Door open with delay
| | | off/1..10000 [off] ms
| | | * Door close with delay
| | | off/1..10000 [off] ms
| | | * Idle period during door reverse move
| | | off/1..3000 [100] ms
| | | * Door motor delayed off at open limit switch
| | | off/1..10000 [250] ms
| | | * Door motor delayed off with close switch
| | | off/1..10000 [250] ms
| | | * Door motor off, if door is closed, after
| | | off/1..240 [off] s
| | | * Door motor off if door is opened, after
| | | off/1..240 [off] s
| | | * Lock debounce timer
| | | off/1..2000 [300] ms
| | | * Lock delay before start
| | | off/1..10000 [off] ms
| | | * Lock delay after stop
| | | off/1..10000 [off] ms
| | | * Sig. debounce time door open monitoring
| | | 100..5000 [2000] ms
| | | * Monitor of time SLC
| | | off/1..10 [3] s
| | | * Duration auto. swing door opener signal
| | | off/1..255 [off] s
| | | * Delay time automatic swing door opener
| | | 100..2000 [250] ms
| | | * Door-close-btn. or car call cancels swing door opener time
| | | - off [Default]
| | | - on
| | |
| | +- Scheduler
| | * Timer 1..16
| |
| +- Floors
| | |
| | +- Special floors
| | | * Lobby floor
| | | off/1..16 [off]
| | | * Parking floor
129