7.8.5.3 Pin-Assignment of the Open-Style-Connector
Pin
Signal
Description
1
CAN_GND
CAN electrical ground
2
CAN_L
CAN-Bus-Signal (dominant low)
3
CAN_SHLD
Optional shielding
4
CAN_H
CAN-Bus-Signal (dominant high)
5
CAN_V+
Optional external power supply
(+24 V)
7.8.6 Node IDs of the CAN Components
Every CANopen component can be identified by a node ID that must
be unambiguous within the CANopen network. If there are two com-
ponents with identical ID connected to the bus, they cannot be selec-
ted by the system.
BÖHNKE + PARTNER assigns the node-IDs according to the
recommendations of the SIG lift control
(
www.CANopen-
Lift.org/wiki/Node-IDs
) as per the following scheme.
Node-ID
[dec.]
CAN1
Local bus
CAN2
well bus
1
bp308 - lift control unit
bp308 – lift control unit G1
2
Drive unit (frequency inverter)
bp308 – lift control unit G2
3
Reserved
bp308 – lift control unit G3
4
Sensor/positioning 1
bp308 – lift control unit G4
5
Sensor/positioning 2
bp308 – lift control unit G5
6
Door control 1 (door A)
bp308 – lift control unit G6
7
Door control 1 (door B)
bp308 – lift control unit G7
8
Door control 1 (door C)
bp308 – lift control unit G8
9
CDG-01 – Gateway
CDG-01 – Gateway 1
10
Reserved
CDG-01 – Gateway 2
11
Reserved
CDG-01 – Gateway 3
12
CLK-03 - car terminal box
CDG-01 – Gateway 4
13
Load-measuring device
CDG-01 – Gateway 5
14
Emergency call unit
CDG-01 – Gateway 6
15
Reserved (emergency call unit)
CDG-01 – Gateway 7
16
Cabin push button unit node 1
CDG-01 – Gateway 8
17-20
Cabin push button unit node 2 - 5
21-70
CAP-01/02 - landing call units landings 1 to 50 (e.g. line 1 or door A)
71-120
CAP-01/02 - landing call units landings 1 to 50 (e.g. line 1 or door B)
125
Default node ID (preset of inventory components such as CAP-01/02 or CIO-01)
126
Flash update bootloader
BÖHNKE + PARTNER supply the lift control unit with all node IDs
already present.
68
Installation Manual System »bp308« – Electrical Installation
Fig. 49
Open-style-plug connector 5
pins
Summary of Contents for bp308
Page 14: ...15...
Page 15: ...16 Installation Manual System bp308 Product Certifications...
Page 54: ...55 Fig 31 Interference suppression circuit diagrams...
Page 114: ...Appendix A Menu Navigation bp308 Version 88D2312 29 08 2013 116...
Page 115: ...117...
Page 150: ...152...
Page 154: ......