Carry out the drive unit check according to the relevant commis-
sioning documentation.
The documentation of the control unit is accompanied by a hard-
copy of all parameters set at factory by BÖHNKE + PARTNER.
Check whether they correspond to the particularities on site. If neces-
sary, adapt the parameters on the display of the bp308 (refer to user
manual bp308.
8.6.1 Checking the Bus Lines
A first impression of the functions of the CAN Bus can be read from
the diagnostics LEDs located at the left side of the display of the
BPC.
For each bus connection there is a LED glowing red on the printed
circuit board, CP1 for CAN1 and CP2 for CAN2. The LEDs demon-
strate the actual operational mode of the corresponding bus. You can
read the status of the LED and its meaning in the following table.
While the system starts, both luminous diodes shine for a short
moment. Both diagnostics LEDs must go out afterwards.
Status
Meaning
Off
CAN-Bus: no error
1 puls
CAN-Bus: warning
2 pulses
CAN-Bus: malfunction
On
CAN-Bus: bus-off (out of oper., after appr. 10 s auto reset )
Flashing
Node-ID error: duplicate node ID in network
Table 1: Meanings of the CAN diagnostics LEDs on the BPC.