INFO
!
To correctly commission our software WinMOS
®
300, please follow
the specifications and instructions of the WinMOS
®
300 manual.
Be aware that you may unwittingly shut-down the lift by entering
incorrect parameters (e.g. setting runtime monitor value too low ).
If you want to connect a modem parallel with an emergency call
system to a mutual telephone connection, first ask approval from
BÖHNKE + PARTNER.
Although WinMOS
®
300 offers options for the lift attendant function,
this will not relieve users from their duty to make sure on site, that the
safety devices of every lift are not purposefully disabled or destroyed
(e.g. emergency stop and emergency call).
Software updates for the control unit or for functions of compon-
ents that are essential for the lift functions may only be carried out if
they are checked by qualified personnel on site.
8.16.1 Commissioning of a Modem
If an analogue modem is used for data remote diagnostics and it has
to correspond to the V.250 standard, the communication parameters
can be entered after having completed the wiring. This primarily
includes the interface (internal modem or data communication port),
RDT300 (DFÜ300) protocol, and telephone number to be called in
case of malfunctions or emergency. You should also set when feed-
back should be given to the service centre: in case of every malfunc-
tion, shutdown only, or none.
8.16.2 Commissioning of a Network Access
If data remote diagnostics is to be carried out via a network access,
you have to set the following parameters :
IP-address: z. B. 192.168.0.119
Subnet-mask: z. B. 255.255.255.0
Gateway: e.g. 192.168.0.2
Port: e.g. 8000 (pre-configuration)
INFO
!
IP-address, Subnet-mask and the gateway are provided to you by the
network administrator. Ports 8000 and 9000 must be available in the
network. The TCP/IP protocol is used .
For more instructions concerning data remote diagnostics, please
refer to the current WinMOS
®
300 manual.
107
Summary of Contents for bp308
Page 14: ...15...
Page 15: ...16 Installation Manual System bp308 Product Certifications...
Page 54: ...55 Fig 31 Interference suppression circuit diagrams...
Page 114: ...Appendix A Menu Navigation bp308 Version 88D2312 29 08 2013 116...
Page 115: ...117...
Page 150: ...152...
Page 154: ......