April 17, 2015
Inspection and Maintenance of Power Unit
(
Continued
)
Adapter Plate
•
Inspect the adapter plate for cracks or chips. Replace the adapter plate if damaged.
•
Inspect o-ring for nicks, cuts or tears. Replace the o-ring if damaged.
Muffler
•
Inspect the muffler for broken or protruding wires. Replace the muffler if damaged.
•
Muffler may be cleaned with parts cleaner to remove build-up. Replace muffler if
excessive build up prevents proper cleaning.
Retainer
•
Inspect the retainer for cracks or chips. Replace the retainer if damaged.
•
Inspect the retainer threads for damage. Replace the retainer if damaged.
Adapter
Plate
O-Ring
Note:
Do not clean the muffler
while it is installed in the
power unit.