Blade Changing
(Continued)
•
Loosen the left cover retaining screw to allow the housing to close.
•
Tighten the right cover retaining screw.
•
With left cover retaining screw ½ turn loose, adjust housing for proper fit.
•
Gently pry the housing open until the blade rotates freely and has enough clearance to
allow the blade to move forward and backward in the housing. Only a slight amount of
movement is necessary.
•
Tighten the cover retaining screws to the recommended torque.
NOTE:
Recommended torque of 30-40 lb-in (3.4-4.5 N-m).
IMPORTANT:
Be sure that the blade is free to move in the housing. If the blade does
not move freely, it may cause the trimmer to overheat.
Housing Slot
Screwdriver
Pivot Support
Point
Left Cover
Retainging Screw