BETTCHER
Industries, Inc.
Maintenance
5-50
Maintenance
Whizard Quantum
®
Air Operating Instructions and Parts
List
Manual No. 102481
April 17, 2015
Inspection and Maintenance of Power Unit
(
Continued
)
Seal Plate
•
Inspect the seal plate I.D. and O.D. for nicks, dents or wear. Replace the seal plate if damaged.
(See Seal Plate Maintenance).
•
Inspect the seal I.D. for nicks, cuts or cracks. Replace the seal if damaged. (See Seal Plate
Maintenance).
Gear Head
•
Inspect the gear head, by rotating the shaft.
•
If the shaft does not rotate, replace the gear head.
•
If you feel a rough or gritty resistance while rotating the shaft, replace the gear head.
•
Re-grease gear head with Max-Z-Lube grease every 80 hours of use.
•
Squeeze grease in through the rotor shaft hole in the bottom of the gear head.
•
Continue to supply grease until clean grease comes out of the grease holes in the ring
gear.
•
This method will thoroughly re-grease gear head and clean out debris trapped in the gear
head.
NOTE:
Use only Max-Z-Lube high performance lubricant.
Seal Plate
Seal
Shaft
Grease Holes
(on both sides)