Chapter 5 Explanations
63
Simulate bulk cone with steel or lead plates
You need steel or lead plates causing the same absorption with
respect to Gamma radiation as the bulk cone. Since this is de-
pendent on the mass per unit area, the steel or lead plate must
have the same mass per unit area as the bulk cone.
The required thickness of the steel plate is determined as follows:
Product coal: 0.5 g/cm
3
Bulk cone diameter: 500 mm
Source: Cs-137
Steel density: 7.8 g/cm³
HVL=0.5x500/7.8=32mm steel
Alternative for lead plate:
HVL=0.5x500/11.3=19mm lead
You may also use several plates in order to get the required thick-
ness of the plate.
The container has to be empty to calculate the switch point, or the
cone end of the bulk cone must be below the monitoring level.
Now use the steel or lead plate and cover the sensitive part of the
detector, i.e. the scintillator. Hold the plate between detector and
container wall. The plate must have the following minimum dimen-
sions in order to cover the entire detector window or the complete
scintillator:
70 x 70 mm for NaI detector
200 x 200 mm for Super-Sens
While the plate is being held in front of the scintillator, read off the
count rate in code 11 and enter this value in code 18.
Calculating the count rate for the switch point
Example with coal
Bulk weight (rho): 0.5 g/cm³
Bulk cone diameter: 50cm
µ for Co-60 source: 0.04
(
µ for Cs-137 source: 0.057)
Empty count rate: 300 cps
Full count rate: 40 cps
I
use
= I
empty
– I
full
I
use
= 300-40 = 260 cps
I = I
full
+ I
use
e
–(µ*rho*d)
I = 40+260*e
–(0.04*0.5*50)
= 136 cps
Input into code 18:
136
Determining the
plate thickness
Calculating the
switch point
Bulk density:
0.5 (g/cm³)
Cs-137
500 mm
Bulk density:
0.5 (g/cm³)
Cs-137
50cm
Summary of Contents for LB4710-050
Page 2: ......
Page 4: ......
Page 8: ......
Page 32: ......
Page 33: ...Chapter 3 Functional Safety Mini Switch LB 471 33...
Page 34: ...Chapter 3 Functional Safety Mini Switch LB 471 34...
Page 35: ...Chapter 3 Functional Safety Mini Switch LB 471 35...
Page 44: ......
Page 58: ......
Page 98: ......
Page 104: ......
Page 110: ...Chapter 14 Certificates Mini Switch LB 471 110...
Page 111: ...Chapter 14 Certificates Mini Switch LB 471 111...
Page 112: ...Chapter 14 Certificates Mini Switch LB 471 112...
Page 113: ...Chapter 14 Certificates Mini Switch LB 471 113 14 2 ATEX Certificate NaI Detector...
Page 114: ...Chapter 14 Certificates Mini Switch LB 471 114...
Page 115: ...Chapter 14 Certificates Mini Switch LB 471 115...
Page 116: ...Chapter 14 Certificates Mini Switch LB 471 116...
Page 117: ...Chapter 14 Certificates Mini Switch LB 471 117 14 3 ATEX Certificate GM Detector...
Page 118: ...Chapter 14 Certificates Mini Switch LB 471 118...
Page 119: ...Chapter 14 Certificates Mini Switch LB 471 119 14 4 EC Declaration of Conformity...
Page 120: ......
Page 141: ...Mini Switch LB 471 141 Notes...
Page 142: ...Mini Switch LB 471 142 Notes...
Page 145: ......
Page 147: ......
Page 149: ......
Page 151: ......
Page 161: ......
Page 195: ......
Page 215: ......
Page 219: ......
Page 223: ...Mini Switch LB 471 78 Notes...
Page 224: ...Mini Switch LB 471 79 Notes...
Page 227: ...Mini Switch LB 471 82 Y Year 21 Z Zero count rate 8 30 32 58...