P.
[Unit] Setting
range
Description
Ex works
451
0..2
Obstacle detection
If the safety edge (SKS) or light barrier (LS) detects an obstacle, the parameter
switches between reverse travel by time, partial door opening or full door opening.
0: Only reverse travel by time
1: Full opening
2: Partial opening if possible, otherwise full opening
0
4E0
1..2
SE1 function
Selection of the input function for safety input SE1
1
4E1
SE1 parameter
Selection of the input profile for safety input SE1 (parameter depends on input
function configured)
0
4E3
0..1
Dead man – safety edge
Selection of whether the safety edge should operate in dead-man mode (P.980 is
1).
0: Safety edge active
1: Safety edge inactive
1
4F0
3..4
Function SE2
Selection of the input function for safety input SE2
3
4F1
Parameter SE2
Selection of the input profile for safety input SE2 (parameter depends on input
function configured)
0
4F4
0..3
SE2 operating direction
The input’s operating direction can be set in P.4F4.
0: CLOSE – with reversal
1: OPEN – with reversal
2: OPEN and CLOSE, STOP function, dead-man travel possible
3: OPEN and CLOSE, STOP function, no travel possible
0
510
5..29
Function FE1
Selection of the input function for input FE1
10
511
Parameter FE1
Selection of the input profile for input FE1 (parameter depends on input function
configured)
00
514
0..1
FE1 direction
For setting the direction with two-way traffic control for this input.
0: Inside
1: Outside
This parameter can only be set if
P.892 is 1.
0
520
6..29
Function FE2
Selection of the input function for input FE2
22
521
Parameter FE2
Selection of the input profile for input FE2 (parameter depends on input function
configured)
00
38