German
English
Description
E.I.E.o.
E.I.E.o.
Calibration of the OPEN limit position required (in dead-man mode or reverse, if the decimal
points are flashing)
E.I.E.I.
E.I.E.I.
Calibration of the partial opening E1 (in dead-man mode)
E.I.E.S.
E.I.E.S.
Calibration of the safety edge (SKS) pre-limit switch position (in maintained operation mode, if
safety edge is OK, otherwise dead-man mode)
E.I.E.b.
E.I.E.b.
Calibration of the floor position (in dead-man mode)
E.I.E.L.
E.I.E.L.
Calibration of the light barrier (LS) muting pre-limit switch (in dead-man mode)
E.I.E.r.
E.I.E.r.
Calibration of the smoke/heat ventilation (RWA) limit switch position (in dead-man mode)
Status messages dead-man mode
These status messages are also used during operation in dead-man mode while a fault is present. After a short time, however, the
active fault message appears permanently whenever the door is still.
German
English
Description
Hd.cL
Hd.cL
Closing in dead-man mode (membrane button: CLOSE)
Hd.oP
Hd.oP
Opening in dead-man mode (membrane button: OPEN)
Hd.Ec
Hd.Ec
CLOSE limit position reached, no further travel in close direction possible in dead-man mode
Hd.Eo
Hd.Eo
OPEN limit position reached, no further travel in open direction possible in dead-man mode
‘Hd’
‘Hd’
Manual
-> dead-man mode in both directions, can be set via
P.980
and is displayed in place of
STOP.
HD.ru
Hd.Jo
Inching mode
-> inching mode in both directions, can be set via
P.980
and is displayed in
place of STOP.
General inputs in the diagnostic mode
German
English
Description
n
n
Cycle display open
u
u
Maintenance cycle display
Sx.xx
Sx.xx
Software version display
HiSt
HiSt
Error message history
SEy.x
SEy.x
Safety input y has status x (x=0..1)
Γy.x
Γy.x
Input y has status x (x=0..1) Example
Γ01.1
input FE1 is active
Error messages
Attention
The cause of the error must first be eliminated before the corresponding message is ac-
knowledged.
The error messages are displayed in front of the general messages and are divided into 3 groups:
Display
Description
F.xxx
Fatal error. The door drive no longer operates. Cover buttons flash quickly.
E.xxx
Minor error. The door drive now only operates in dead-man mode (possibly dependent upon direction). Cover
buttons flash slowly.
I.xxx
Information. Individual door functions are disrupted, e.g. if parameterisation is missing or maintenance is due
x.xxx.
Active error. When this has been rectified, it must be acknowledged by pressing and holding the rotary-push but-
ton.
x.xxx
Active error. When this has been corrected, it does not have to be acknowledged
xxxx.
Corrected error. It must be acknowledged by pressing and holding the rotary-push button (DDT).
48