Selection of parameters
7-segment display
DDT (R), (L), (RR), (LL)
Select the desired parameters.
A T T E N T I O N:
Not all parameters can be dir-
ectly viewed or changed, de-
pending on the selected
para-
meterisation level (operator
level P.999: 0000 or techni-
cian level).
The parameter value can be
viewed or changed (see be-
low).
Display varies with selection.
P
.
.
.
Parameter editing
7-segment display
1.
Control unit in the paramet-
erisation level.
Display of the desired para-
meter name.
P
0
1
0
2.
DDT (T)
Briefly activate the rotary-push
button to open the parameter.
The current parameter value is
displayed.
5
3.
DDT (R), (RR)
Turn the rotary-push button
clockwise in order to increase
the parameter value.
If the current valid parameter
value is changed, the decimal
point flashes.
6.*
Or
DDT (L), (LL)
Turn the rotary-push button
anticlockwise in order to re-
duce the parameter value.
4.*
4.
DDT (T)
Briefly press the rotary-push
button in order to discard the
set parameter value.
Abort, and the original para-
meter value is displayed once
again.
5
Or
DDT (TT)
Press and hold the rotary-push
button in order to save the set
parameter value.
The parameter can be con-
sidered saved when the value
no longer flashes.
6
5.
DDT (T)
Briefly press the rotary-push
button in order to switch to the
parameter name display.
Display of the parameter
name.
P
0
1
0
Leaving the parameterisation level
7-segment display
1.
DDT (TT)
Press and hold the rotary-push
button in order to leave the
parameterisation level immedi-
ately. The door operation is
active once more.
The last saved value is re-
tained automatically.
.
.
.
.
2.
Switch off the door con-
trol unit
Turn off the power supply to all
poles. (Observe safety instruc-
tions).
The 7-segment display goes
off.
3.
Switch the PAR
switch to OFF
Parameterisation levels are
deactivated, close the hous-
ing.
4.
Switch on the door con-
trol unit
*
)
The decimal point flashes.
The procedure shown above in tabular form is illustrated below: P.010: 6.
After approx. 30 mins. the parameterisation level is automatically reset to the status level.
In order to access the parameterisation level again, the control unit must be turned off
briefly and then turned back on again. You must enter the password again for the techni-
cian level.