Function
Profile
Description
8.XX
Pre-limit-switch (VES)
(CLOSE limit position)
Mechanical limit switching – Testing is initiated underneath the pre-limit switch with a pressure-wave
safety edge. P.215 can be used to set whether the edge underneath the pre-limit switch is ignored
(0) or whether the door is stopped when the edge is triggered (1).
8.00
NC – normally closed
8.01
NO – normally open
9.XX
Partial opening limit
switch
Mechanical limit switching – If an input with partial opening is active, the partial opening limit switch is
approached instead of the OPEN limit switch.
9.00
NC – normally closed
9.01
NO – normally open
10.XX
Overload switch
If this is activated, the control unit switches to fault F330 and no travel is possible. The input is de-
bounced 100 ms.
10.00
NC – normally closed
10.01
NO – normally open
11.XX
Drive command OPEN
For radio, only "Door visible = No" can be parameterised. An NO – normally open contact must be
used as the contact type.
Maintained operation
Pressing the OPEN button opens the door in maintained operation mode. When the OPEN or partial
opening limit position is reached, the door stops. If the OPEN button is pressed while the door is
closing, the door stops instantly and moves to the OPEN or partial opening limit position after a delay
of 0.5 s. If automatic closing is activated, the door is closed again once the stay-open time has
elapsed. An active OPEN command in maintained operation is a continuous command. The door
opens again when it is interrupted by a command.
Dead-man
In the dead-man operating mode, the door will only move whilst a travel button is pressed. If two drive
commands are active, or if the drive command is active for longer than 60 s, the error code E.117 ap-
pears. This must be acknowledged. If the door is visible: No, dead-man operation is not possible.
11.00
Door visible: No | Stay-open time: 1 | Limit position: OPEN
11.01
Door visible: No | Stay-open time: 1 | Limit position: Partial opening
11.02
Door visible: No | Stay-open time: 1 | Limit position: Selection switch
11.03
Door visible: No | Stay-open time: 2 | Limit position: OPEN
11.04
Door visible: No | Stay-open time: 2 | Limit position: Partial opening
11.05
Door visible: No | Stay-open time: 2 | Limit position: Selection switch
11.06
Door visible: Yes | Stay-open time: 1 | Limit position: OPEN
11.07
Door visible: Yes | Stay-open time: 1 | Limit position: Partial opening
11.08
Door visible: Yes | Stay-open time: 1 | Limit position: Selection switch
11.09
Door visible: Yes | Stay-open time: 2 | Limit position: OPEN
11.10
Door visible: Yes | Stay-open time: 2 | Limit position: Partial opening
11.11
Door visible: Yes | Stay-open time: 2 | Limit position: Selection switch
21