Technician level
For additional settings, you must switch to the password-protected technician level (P.999: 0410).
Password entry
DDT activation
Explanation
7-segment display
1. PAR = ON
Control unit in the status level
When the door is stationary,
the parameterisation level can
be accessed.
_.*
E
c
_
2. DDT (T)
Control unit in the paramet-
erisation level
Selection of the desired para-
meter.
P.
9
9
9
3. DDT (T)
Briefly press the rotary-push
button
Display of the current pass-
word
0
0
0
0
4. DDT (R)
Turn the rotary-push button
clockwise
0
0
0
1
5. DDT (RR/LL)
Turn the rotary-push button
clockwise or anticlockwise to
set the number.
Setting the password
0
4
1
0
6. DDT (TT)
Press and hold the rotary-push
button in order to confirm the
set password.
Wait until display no longer
flashes.
0
4
1
0
7. DDT (T)
Briefly press the rotary-push
button
Further parameters have been
activated.
P.
9
9
9
*
)
The decimal point flashes.
General operating information regarding parameterisation
3 parameterisation levels are available. In the operator level, different times can be set without using a password. For further set-
tings, you must switch to the password-protected technician level. The door manufacturer level with access to further parameters
requires a password. After setting the parameters, set the DIP switch PAR to OFF. This prevents unintentional changes.
Changing parameters
Caution
After changing the parameters, set the DIP switch PAR to OFF.
Opening the parameterisation level
7-segment display
1.
Switch off the door con-
trol unit
Turn off the power supply to all
poles
(Observe safety instructions).
The 7-segment display goes
off.
2.
Switch the PAR
switch to ON
The parameterisation levels
are activated; close the hous-
ing.
3.
Switch on the door con-
trol unit
Switch on the control unit.
When the DIP switch PAR=ON,
the first decimal point flashes.
Content of the display de-
pends on the control unit
status.
.*
4.
DDT (T)
Briefly activate the rotary-push
button.
The control unit switches to
the parameterisation level.
During parameterisation, the
door cannot be operated. If
the DIP switch PAR=ON, you
can switch to P.999 in the
technician level after inputting
the password.
P
9
9
9
13