Step
Description
7-segment display
7. UPPER limit position
OPEN but-
ton
Travel to the desired OPEN limit position.
E.
i.
E.
o.
8. Saving the limit posi-
tion
DDT
(TT)
To save the position, press and hold the rotary-push button until
the display no longer flashes.
9. UPPER limit position
– inching mode
OPEN but-
ton
DOWN but-
ton
For fine adjustment of the limit position, the control unit moves
in inching mode. The decimal points of the 7-segment display
flash.
E.
E
i.
i
E.
E
o.
o
10. Saving the limit posi-
tion
DDT
(TT)
To save the position, press and hold the rotary-push button until
the display no longer flashes.
11. Pre-limit switch
DOWN but-
ton
With a pre-limit-switch
Place the VES gauge or a similar implement (height: 30...40
mm, e.g. wooden slat, pipe or similar) on the ground under the
door, in the middle of the clearance of the door opening.
E.
i.
E.
s.
When the CLOSE button is pressed, the control unit moves the
door in maintained operation mode (impulse mode) to the VES
gauge. The control unit saves this point as an internal pre-limit
switch (VES) and then moves away from the VES gauge. If the
door hits another obstacle, press the CLOSE button again.
Without a pre-limit-switch
Move the door to the CLOSED position.
Safety edge not connected
The control unit moves the door in dead-man mode. Move the
lower edge of the door to approx. 20 mm above the ground.
12. Saving the limit posi-
tion
DDT
(TT)
To save the position, press and hold the rotary-push button until
the display no longer flashes.
13. Floor adjustment
DOWN but-
ton
When using the function "floor adjustment" (
P.216: 1
) Move
the door downwards until the control unit stops the door auto-
matically in the CLOSE limit position. Save the limit position by
pressing the DDT (TT).
E.
i.
E.
b.
14. Saving the limit posi-
tion
DDT
(TT)
To save the position, press and hold the rotary-push button until
the display no longer flashes.
15. Partial opening
Setting the partial opening when
P.244 is 3
. Open to the de-
sired position.
Save the partial opening position by pressing the DDT (TT). On
the display, the message "-E1-" appears.
If a partial opening position is not needed, move the door to the
OPEN limit position and save the limit position by pressing the
DDT (TT).
E.
i.
E.
1.
16. Saving the limit posi-
tion
DDT
(TT)
To save the position, press and hold the rotary-push button until
the display no longer flashes.
Now the setting of the limit positions is complete.