![background image](http://html1.mh-extra.com/html/barco/transform-a/transform-a_user-manual_3826173103.webp)
4. Operating
Barco – TransForm A - Workstation for Windows – DOC-3266-2 – Revision 16 – August 2007
____________________________________________________________
4-23
Configuring video streams
The parameters of a video stream must be defined in this
Stream Params Editor
, before the S
TREAMING
V
IDEO
C
ARD
can display it. Once defined it is available for every S
TREAMING
V
IDEO
C
ARD
in the system. To open the
Stream
Params Editor
press
Edit
on the control panel.
Pressing the
Add
button adds a new stream with the entered name into the
Streams
list. The parameters that
are displayed at that time are saved together with it. If an entry with the same name already exists its parame-
ters are not changed. Pressing the
Apply
button applies the displayed parameters to the hardware. In that way
changes can be controlled directly. Pressing the
OK
button applies the parameters to the hardware and to the
registry. Pressing the
Cancel
button closes the window, anyhow changes that are already confirmed with the
Add
or
Delete
button cannot be revoked.
Stream parameters for streams of Streaming Video Card SVC-1, SVC-2 and J2K are commonly
stored and listed. If using different type of Streaming Video Cards in one system take care
to select stream parameters that suite the card type!
Figure 4-9
Stream Parameter Editor of the S
TREAMING
V
IDEO
C
ARD
SVC-1 or SVC-2
The configuration of a stream differs depending on using S
TREAMING
V
IDEO
C
ARD
SVC-1 or S
TREAMING
V
IDEO
C
ARD
SVC-2:
Streaming Video Card SVC-2
Stream
A list of all video streams in alphabetic order.
Stream names have to start with a letter; initial digits may not be used!
Decoder Control
IP Address
enter a unicast IP address, to receive a unicast stream,
enter a multicast IP address, to receive a multicast stream
Port
Stream port, appendant to the IP address.
IP Protocol
Not applicable, but the default value
udp
should not be changed.
Stream Protocol
Not applicable, but the default value
auto
should not be changed.
PID
A specific encoder configuration is selected by entering the suitable number. Please se-
lect the respective configuration number from the encoder configuration list below.
Skip bytes at
Start / End
Not applicable, but the default value
0
should not be changed.