![Barco TransForm A User Manual Download Page 25](http://html1.mh-extra.com/html/barco/transform-a/transform-a_user-manual_3826173025.webp)
3. Getting started
Barco – TransForm A - Workstation for Windows – DOC-3266-2 – Revision 16 – August 2007
_____________________________________________________________
3-8
The back
11-22
9
10
25
24
23
23
26
9
link interface card
10
CPU board
11-22
Barco’s expansion cards
23
ventilation slots
24
mains connection of power module
25
LED: power status of power module
permanent red
standby mode: Power applies at the module but the device is not
switched on.
permanent green
power module OK, power output OK
off
power connection is interrupted
26
connection for equipotential bonding conductor
Figure 3-8
Rear view of O
MNI
B
US
A12
In total there are 14 card slots visible from the back, with the left two positions having a fixed assignment for
the
link interface card
[9] and the
CPU board
[10].
Graphic cards
,
OmniScalers
and
input cards
[11-22] follow,
depending on the configuration of T
RANS
F
ORM
A.
On the left there are three power modules each with a
mains connection
[24] and an LED to indicate the
power
status
[25]. On the lower part there is a
connection for the equipotential bondig conductor
[26].
To disconnect the O
MNI
B
US
A12
from the power supply all power cords have to be pulled of
the mains connection [24]. Therefore the back panel has to be easily accessible!
To protect the O
MNI
B
US
A12
from overheating, the air supply openings in the case shall be
kept free of obstructions!
To ensure power redundancy
take care to connect each of the power modules to an
independent power net.