![Barco TransForm A User Manual Download Page 164](http://html1.mh-extra.com/html/barco/transform-a/transform-a_user-manual_3826173164.webp)
6. Advanced configuration
Barco – TransForm A - Workstation for Windows – DOC-3266-2 – Revision 16 – August 2007
____________________________________________________________
6-37
6.1.12
Genlock
The refresh rate of the projection module is in general not synchronized to the refresh rate of the video. As a
result the display of the video can look jerky. Genlocking can avoid this unwanted behavior by providing the data
signals to the projector at a refresh rate which is perfectly adapted to one video source. A Source of a Q
UAD
A
NA-
LOG
V
IDEO
C
ARD
, a D
UAL
DVI
I
NPUT
C
ARD
or a S
TREAMING
V
IDEO
C
ARD
can be used for genlocking.
Genlock is available in an OmniBus configuration only!
Usage
Genlock is controlled by means of the command line tool
genlock
. To use it open a command prompt and en-
ter
genlock
with the respective options, like e.g.:
C:>
genlock /sel:frg0
to specify the input card, that provides the video source that is used for genlocking.
The following options are available:
Option
calling
genlock
without option returns the complete options list
/start
initializes the genlock utility
this must first be entered to enable the further functionality
/sel:[<FRG-name>
ª
|EXT|INT]
<FRG-name>
selects the input card, whose signal shall be used for genlocking; ei-
ther the system default names or the names defined in the switcher definition file,
see section
4.3.2 Naming of video channels and video sources
, can be used.
EXT
selects external input.
INT
selects the first UGX or AGX
G
RAPHIC
C
ARD
.
/on
data on the projection modules is displayed in sync
Before using
/on
first a source must be selected with the option
/sel
/off
displaying in sync is stopped.
/sts
returns for all graphic cards the state of the parameters that are relevant for genlock-
ing
/stop
de-initializes the genlock utility
this should be called to properly exit the
genlock
tool
Table 6-24
Options of genlock
The actual state of the genlock utility is stored in the registry. Therefore after a reboot
automatically the same genlock settings as before are applied.
When using genlock make sure, that the cabling for genlock has been established as
explained in section
.
If an external signal is connected only external may be selected. If selecting internal or a
video signal it will be disturbed by the external signal. Therefore the external signal should
be unplugged before switching to an other type of genlock!