4.3.1 RS-485 Remote Control
The RS-485 Remote Control connector is a 9-pins SubD male connector. All important modulator
parameters such as RF level, modulation depth, audio deviation and all possible functional selections
can be remotely controlled from a PC with B
ARCO
’
S ROSA
software and/or the client-server
ROSA
/
COPERNICUS
system. This makes it possible to use the P
ULSAR
in applications such as digital to
analog nodes in super trunk systems and headends in rural or remote areas. Using the P
ULSAR
with
other remote controllable equipment, such as
FSM
860,
SAT
200,
QUASAR
, allows the operator to have
complete control over the headend.
Pin
Function
Pin
Function
1
Not Connected
6
Not Connected
2
TxB
7
Floating
3
RxB
8
Not Connected
4
TxA
9
Not Connected
RS
485
1
9
5
RxA
•
Pin 7 : floating or grounded, selectable with bridge BR2 on the mainboard.
4.3.2 Audio Input - Status & Control
4.3.2.1 Audio Inputs
The upper row of the screw terminal is used as input for the baseband audio signal, the configuration
of the terminal is:
PIN
Function
PIN
Function
1
MAIN input left or mono (+)
7
AUX input left or mono (+)
2
MAIN input left or mono (-)
8
AUX input left or mono (-)
3
Ground
9
Ground
4
MAIN input right (+)
10
AUX input right (+)
5
MAIN input right (-)
11
AUX input right (-)
6
Ground
12
Ground
AUDIO INPUTS
STATUS & CONTROL
I
II
12
1
Summary of Contents for PULSAR BG
Page 2: ......
Page 6: ......
Page 10: ......
Page 12: ......
Page 36: ...Installation Filter Module PULSAR Page 6 2...
Page 42: ......
Page 47: ...PULSAR Audio Video Auxiliary Input Page 5...
Page 50: ......
Page 56: ......
Page 68: ......
Page 83: ...PULSAR BG Composite IF Aux Input Page 7...
Page 84: ......
Page 88: ......
Page 92: ......
Page 104: ......
Page 117: ...PULSAR BG Reference Carrier Output Page 3...
Page 118: ......