126
PDS • User’s Guide
_K==oÉãçíÉ=`çåíêçä
Remote Commands
•
Parameters
:
-i (input): 5-6 (PDS-701) 5-8 (PDS-901 and PDS-902)
-t (EDID type): 0 - analog, 1 - digital (Default: 1)
•
Query Format
: EDIDTYPE -i(input) -?
•
Query Response
: EDIDTYPE -i(input) -t (EDID type) --min 0 --max 1
•
List Format
: EDIDTYPE -i(input)
•
List Response
:
0:"Analog"
1:"Digital"
cobbwb
•
Description
: Freezes the input on program.
•
Command Format
: FREEZE -m (mode)
•
Parameters
: -m (mode): 0-off, 1-on (Default: off)
•
Query Format
: FREEZE -?
•
Query Response
: FREEZE -m (mode) --min 0 --max 1
f^ag
•
Description
: Selects the input path to be adjusted (preview or program). This
command is valid only for the PDS-902.
•
Command Format
: IADJ -p (path)
•
Parameters
:-p (path): 0-preview, 1-program
•
Query Format
: IADJ -?
•
Query Response
: IADJ -p (path)
•
List Format
: IADJ --list
•
List Response
:
0: "Preview"
1: "Program"
f^agopq
•
Description
: Reset the input timing parameters to default values for analog. This
command is only available for analog input types.
•
Command Format
: IADJRST -i (input)
•
Parameters
: -i (input): 1 - 6 (PDS-701); 1 - 8 (PDS-901/902)
(5 - 8 only if type is analog)
•
Query Format
: N/A
•
Query Response
: N/A
f^o=
•
Description
: Adjust Input Aspect Ratio
Summary of Contents for PDS
Page 1: ...r d map Manual 26 1204000 00 Revision 00...
Page 36: ...22 PDS User s Guide 3 Installation Format Connection Table...
Page 98: ...84 PDS User s Guide 4 Operation Using Front Panel Lockout...
Page 118: ...104 PDS User s Guide 6 Upgrading Firmware Upgrading Firmware Using the Web Upgrade...
Page 121: ...PDS User s Guide 107 K p Output Specifications...
Page 174: ...160 PDS User s Guide Index...