6. Installation of Projection System
OverView D 50" – DOC-3303-5 – installation manual – Revision 10 – September 2006
September 2006
September 2006
September 2006 ________________________________
________________________________
________________________________
_________________________________________________________
_________________________
_________________________
_________________________6-9
The 3200 K filter assembly looks like this:
The fixation angle will be fixed to the drills of the removed black sheet metal cover.
The activation handle allows sliding the filter in and out.
In-position: the filter is inactive, color temperature = 6500K.
Out-position: the filter is active, color temperature = 3200K
Insert the filter assembly into the slit of the projection unit. The activation handle shows towards the lens.
Use 2x screws B360322 to attach the fixation angle to the projection unit.
Use 1x screw B360322 to cover the M3 drill in the base plate.
filter activation handle
towards lens
fixation angle
towards color wheel