1. Safety
For example, projectors that have a HD greater than 1 m and emit light into an uncontrolled area where persons may be present
should be positioned in accordance with “the
fi
xed projector installation” parameters, resulting in a HD that does not extend into
the audience area unless the beam is at least 2.0 meter above the
fl
oor level. In environments where unrestrained behavior is
reasonably foreseeable, the minimum separation height should be greater than or equal to 3.0 meter to prevent potential exposure,
for example by an individual sitting on another individual’s shoulders, within the HD. Suf
fi
ciently large separation height may be
achieved by mounting the image projector on the ceiling or through the use of physical barriers.
For LIPs (Laser Illuminated Projectors) installed in the USA market the above limits do not apply. Lip’s for installations other than in
cinema theaters shall be installed at a height vertically above the
fl
oor such that the bottom plane of the Hazard Zone shall be no
lower than 3 meters above the
fl
oor. Horizontal clearance to the hazard zone shall be 2.5 meters. Any human access horizontally
to the Hazard Zone, if applicable, shall be restricted by barriers. If human access is possible in an unsupervised environment, the
horizontal or vertical clearances shall be increased to prevent exposure to the RG3 hazard zone.
In addition for temporary installations (e.g.: rental and staging, lease, events …) the following requirements apply:
•
This product can only be installed by Barco or sold or leased only to valid laser light show variance holders. In other words
our installers are required to have an approved laser light show variance. Such installers may currently hold a valid variance
for production of Class IIIb and IV laser light shows and/or for incorporation of the RG3 LIPs into their shows. Dealers and
distributors are also required to obtain a valid laser light show variance.
•
This product shall be located in such a way that all propagating beam paths within the Restriction Zone, and the audience can
be directly observed at all times.
•
Effects other than front or rear screen projections shall not be performed.
•
Communication shall be maintained with other personnel assisting in surveillance of the LIP projection.
•
In the event of any unsafe condition, immediately terminates (or designate the termination) of LIP projection light.
Install one or more readily accessible controls to immediately terminate LIP projection light. The power input at the projector side
is considered as a reliable disconnect device. When required to switch off the projector, disconnect the power cord at the projector
side. In case the power input at the projector side is not accessible (e.g. truss mount), the socket outlet supplying the projector shall
be installed nearby the projector and be easily accessible, or a readily accessible general disconnect device shall be incorporated
in the
fi
xed wiring.
Laser light shows can be requested via the FDA online eSubmitter portal or via FDA Form FDA Form 3147 referencing to Barco’s
variance approval 2016-V-0144.
RA
TH
PR
RZ
HD
SW
1m
SW
SW
SW
HD
SH
RA
TH
RZ
SH
(B) TOP VIEW
(A) SIDE VIEW
Image 1-1
A
Side view.
B
Top view.
RA Restricted Access location (boot area of projector).
PR Projector.
TH Theater.
RZ Restriction Zone in the theater.
SH Separation Height.
SW Separation Width.
Based on national requirements, no person is allowed to enter the projected beam within the zone between the projection lens and
the related hazard distance (HD). This shall be physically impossible by creating suf
fi
cient separation height or by placing barriers.
The minimum separation height takes into account the surface upon which persons other than operator, performers or employees
are permitted to stand.
On image 1-2 a typical setup is displayed. It must be veri
fi
ed if these minimum requirements are met. If required a restricted zone
(RZ) in the theater must be established. This can be done by using physical barrier, like a red rope as illustrated in image 1-2.
The restricted area sticker can be replaced by a sticker with only the symbol.
R5906730 HDF WLP SERIES 01/08/2017
13
Summary of Contents for HDF-W30LP
Page 1: ...HDF WLP series User and Installation manual R5906730 05 01 08 2017...
Page 4: ......
Page 10: ...Table of contents 6 R5906730 HDF WLP SERIES 01 08 2017...
Page 78: ...8 Input Communication 74 R5906730 HDF WLP SERIES 01 08 2017...
Page 90: ...9 Getting started 86 R5906730 HDF WLP SERIES 01 08 2017...
Page 94: ...10 Software upgrade Image 10 5 90 R5906730 HDF WLP SERIES 01 08 2017...
Page 95: ...10 Software upgrade Image 10 6 R5906730 HDF WLP SERIES 01 08 2017 91...
Page 98: ...10 Software upgrade Image 10 11 94 R5906730 HDF WLP SERIES 01 08 2017...
Page 99: ...10 Software upgrade Image 10 12 R5906730 HDF WLP SERIES 01 08 2017 95...
Page 100: ...10 Software upgrade Image 10 13 10 Clear the history log 96 R5906730 HDF WLP SERIES 01 08 2017...
Page 108: ...11 Quick set up adjustment 104 R5906730 HDF WLP SERIES 01 08 2017...
Page 172: ...15 Layout 168 R5906730 HDF WLP SERIES 01 08 2017...
Page 224: ...17 Alignment 220 R5906730 HDF WLP SERIES 01 08 2017...
Page 258: ...18 Projector Control 254 R5906730 HDF WLP SERIES 01 08 2017...
Page 272: ...19 Service 268 R5906730 HDF WLP SERIES 01 08 2017...
Page 282: ...21 Maintenance procedures 278 R5906730 HDF WLP SERIES 01 08 2017...
Page 300: ...C Standard source files 296 R5906730 HDF WLP SERIES 01 08 2017...
Page 304: ...D DMX chart 300 R5906730 HDF WLP SERIES 01 08 2017...
Page 310: ...E Stacking HDF WLP series projectors 306 R5906730 HDF WLP SERIES 01 08 2017...