WORD #
WORD NAME
DATA TYPE
3-5
reserved
16-bit integer
PLC Assembly Instance 117 (0×75) - 34 Registers (Sensor Inputs/PLC Outputs) O > T
Data transfer
direction:
Originator (PLC) to Target (VE). Assembly Instance 117 (0×75) is a group of registers used for the FTP
file
name.
WORD #
WORD NAME
DATA TYPE
0
Input Bits Register (see
on page 158)
16-bit integer
1-2
Product Change Number
32-bit integer
3-5
reserved
16-bit integer
6-7
FTP Filename String Length
32-bit integer
8-33
FTP Filename String
String (52 characters)
13.3.2 Outputs from the Sensor (Inputs to the PLC)
PLC Assembly Instance 100 (0×64) - 30 Registers (Sensor Outputs/PLC Inputs) T > O
Data transfer
direction:
Target (VE) to Originator (PLC). Assembly Instance 100 (0×64) is a small block of registers providing basic
inspection
results and 13
user-configurable
registers for
tool-specific
results from the VE Series camera.
WORD #
RESULT
DATA TYPE
0
Input Bits ACK Register (see
on page 158)
16-bit integer
1
Output Bits Register (see
on page 158)
16-bit integer
2-3
Error Code
32-bit integer
4-5
Inspection
Number
32-bit integer
6-7
Frame Count
32-bit integer
8-9
Pass Count
32-bit integer
10-11
Fail Count
32-bit integer
12-13
Missed Triggers
32-bit integer
14-15
Current
Inspection
Time
32-bit
float
16
Sensor Pass/Fail Bits (see
on page 158)
16-bit integer
17-29
User-defined
(see
on page 159)
Selection
dependent
PLC Assembly Instance 101 (0×65) - 240 Registers (Sensor Outputs/PLC Inputs) T > O
Data transfer
direction:
Target (VE) to Originator (PLC). Assembly Instance 101 (0×65) is a large block of registers that provides both
basic
inspection
results and 223
user-configurable
registers for
tool-specific
results.
WORD #
WORD NAME
DATA TYPE
0
Input Bits ACK Register (see
on page 158)
16-bit integer
1
Output Bits Register (see
on page 158)
16-bit integer
2-3
Error Code
32-bit integer
4-5
Inspection
Number
32-bit integer
6-7
Frame Count
32-bit integer
8-9
Pass Count
32-bit integer
10-11
Fail Count
32-bit integer
12-13
Missed Triggers
32-bit integer
14-15
Current
Inspection
Time
32-bit
float
VE Series Smart Camera
www.bannerengineering.com - Tel: 763.544.3164