Percent Match
Set the percent match to indicate the quality of the match (10% is a slight match; 100% is a perfect match). The default is 60%.
Figure 213. Percent Match
Rotation
Range
Select the range within which the
pattern
may be rotated and
still
count as a match to the reference image. The default is 45 degrees.
Figure 214.
Rotation
Range
The larger the
Rotation
Range, the longer the
execution
time
of the tool. In general, this means that the
execution
time
of the
inspection
increases.
Precision
Select either Fine Search or Coarse Search. Course Search is the default. Fine Search is slower but provides more accurate results.
Figure 215. Precision
Timeout
Set the amount of
time
the tool looks for the
pattern
before it stops.
Figure 216. Timeout
Use as Reference
Choose whether to use this tool as a reference for other tools.
Figure 217. Use As Reference—No Reference Point Set
Figure 218. Use As Reference—Reference Point Set
VE Series Smart Camera
www.bannerengineering.com - Tel: 763.544.3164
113