The Banner Image Export Sample Program installs
automatically
when the Vision Manager
software
is installed. The source code to
write your own
application
is located at C:\Users\Public\Documents\Banner Vision Manager\Sample Programs\Source\Image Export.
Figure 289. Image Export Sample
Application
12.1.5 Image Export: FTP
Image Export FTP supports
exporting
images over an FTP
connection.
Navigate: System
Settings
>
Communications
> Image Export, select which images to export, and select FTP from the Ethernet Protocol
list.
File Name Format
Set which elements to include in the
file
names of images that are exported using FTP. Result shows a sample
file
name. If
nothing is selected, the frame number is used as the
file
name.
•
Inspection
Pass/Fail—Adds P or F to the
file
name.
• Device Name—Adds the name of the device to the
file
name. For example, VE202G21.
•
Inspection
Slot Number—Adds S# to the
file
name. For example, S1.
•
Inspection
Name—Adds the name of the
inspection
to the
file
name. For example,
Inspection
01.
• Frame Number—Adds N#### to the
file
name. For example, N1234.
• Custom String—Select and enter the desired text to include in each
file
name. The maximum number of characters is
100.
• Industrial Protocol String—Adds custom text to the
file
name from the industrial protocol. The maximum number of
characters is 52. See the
section
on your protocol for
information
on how to set the custom string (Input String). The
string, if available, displays. The string is not saved and cycling the power will delete the string.
To assign the Industrial Protocol string:
1. Make sure that the Input String bit on the Input Bits Register is set to 0.
2. Write the desired string length into the FTP Filename String Length area.
3. Write the desired string content into the FTP Filename String area.
4. Set the Input String bit to 1 to apply the custom string.
After
the input string is saved in the system, the Input
String Ack bit will be set to 1.
Note: The
specific
industrial protocol must be enabled on the Industrial Protocols tab.
For register
information
and input bits, see the following
sections:
◦
◦
◦
on page 182
◦
on page 192
This is an example
file
name that uses most of the File Name Format
options:
PVE202G21S1Inspection
01N1234.bmp. This
example does not include any custom strings or industrial protocol strings.