Technical data
Automation PC 3100 User's manual V 1.00
Translation of the original documentation
29
2.2.3.1.5 Ambient temperature during storage and transport
The following table provides an overview of the minimum and maximum ambient temperatures for storing and
transporting the complete system. Limitations are possible due to individual components.
Component
Model number
Storage
Transport
System unit
5APC3100.KBUx-000
-20 to 60°C
-20 to 60°C
5CFAST.xxxx-00
-50 to 100°C
-50 to 100°C
CFast cards
5CFAST.xxxx-10
-40 to 85°C
-40 to 85°C
5ACCLI02.DPO0-000
-20 to 60°C
-20 to 60°C
5ACCLI02.SDL0-000
-20 to 60°C
-20 to 60°C
Graphics options
5ACCLI02.SD40-000
-20 to 60°C
-20 to 60°C
5AC901.I232-00
-20 to 60°C
-20 to 60°C
5AC901.I485-00
-20 to 60°C
-20 to 60°C
5AC901.ICAN-00
-20 to 60°C
-20 to 60°C
5AC901.ICAN-01
-20 to 60°C
-20 to 60°C
5AC901.IHDA-00
-20 to 60°C
-20 to 60°C
5AC901.IRDY-00
-20 to 60°C
-20 to 60°C
5AC901.IPLK-00
-20 to 60°C
-20 to 60°C
5AC901.ISIO-00
-20 to 60°C
-20 to 60°C
5AC901.ISRM-00
-20 to 60°C
-20 to 60°C
5AC901.IETH-00
-20 to 60°C
-20 to 60°C
5ACCIF02.CANE-000
-20 to 60°C
-20 to 60°C
Interface options
5ACCIF02.FPLK-000
-20 to 60°C
-20 to 60°C
Table 8: System units, CFast cards, interface options - Ambient temperature during storage and transport
2.2.3.1.6 Temperature monitoring
Sensors monitor temperature values at various areas in the APC3100. For the position of temperature sensors,
see
"Temperature sensor positions" on page 30
. The values specified in this section represent the defined
maximum temperature at this measuring point. If the temperature is exceeded, no alarm is triggered.
Temperatures
1)
can be read out in different ways in approved operating systems:
•
BIOS
•
B&R Control Center
2)
•
B&R ADI Development Kit
2)
•
B&R ADI .NET SDK
2)
•
B&R HMI Service Center
2)
•
B&R HMI Diagnose
2)
•
B&R PVI ADI line
2)
•
B&R ADI SNMP Agent
2)
•
Automation Runtime library
2)
For applications that do not run in approved operating systems, temperatures can be evaluated using the MTCX
Development Kit. In addition to the MTCX Development Kit, sample programs in EFI are also available.
In addition, the CFast cards available from B&R for APC3100 systems are equipped with Self-Monitoring, Analysis
and Reporting Technology (S.M.A.R.T). This means that various parameters, such as temperature, can be read
out using software (e.g. HDD Thermometer, freeware) in approved Microsoft Windows operating systems.
1)
The measured temperature is a guide value for the immediate ambient temperature, but it may have been influenced by neighboring components.
2)
Drivers for approved operating systems can be downloaded at no cost from the Downloads section of the B&R website (
).