Technical data
Automation PC 3100 User's manual V 1.00
Translation of the original documentation
31
2.2.3.2 Relative humidity
Component
Model number
Operation
Storage
Transport
System units
5APC3100.KBUx-000
5 to 90%
5 to 95%
5 to 95%
5CFAST.xxxx-00
Max. 85% at 85°C
Max. 85% at 85°C
Max. 85% at 85°C
CFast cards
5CFAST.xxxx-10
Max. 85% at 85°C
Max. 85% at 85°C
Max. 85% at 85°C
5ACCLI02.DPO0-000
5 to 90%
5 to 95%
5 to 95%
5ACCLI02.SDL0-000
5 to 90%
5 to 95%
5 to 95%
Graphics options
5ACCLI02.SD40-000
5 to 90%
5 to 95%
5 to 95%
5AC901.I485-00
5 to 90%
5 to 95%
5 to 95%
5AC901.ICAN-00
5 to 90%
5 to 95%
5 to 95%
5AC901.ICAN-01
5 to 90%
5 to 95%
5 to 95%
5AC901.IHDA-00
5 to 90%
5 to 95%
5 to 95%
5AC901.IRDY-00
5 to 90%
5 to 95%
5 to 95%
5AC901.IPLK-00
5 to 90%
5 to 95%
5 to 95%
5AC901.ISIO-00
5 to 90%
5 to 95%
5 to 95%
5AC901.ISRM-00
5 to 90%
5 to 95%
5 to 95%
5AC901.IETH-00
5 to 90%
5 to 95%
5 to 95%
5AC901.I232-00
5 to 90%
5 to 95%
5 to 95%
5ACCIF02.CANE-000
5 to 90%
5 to 95%
5 to 95%
Interface options
5ACCIF02.FPLK-000
5 to 90%
5 to 95%
5 to 95%
Table 10: System units, graphics option, IF options, CFast cards - Relative humidity
2.2.3.3 Vibration
The following table provides an overview of the maximum vibration values of the complete system. Limitations are
possible due to individual components.
Automation PC
Operation
1)
Storage
1)2)
Transport
1)2)
Continuous
Periodic
With CFast card
2 to 9 Hz:
1.75 mm amplitude
9 to 200 Hz: 0.5 g
2 to 9 Hz:
3.5 mm amplitude
9 to 200 Hz: 1 g
2 to 8 Hz: 7.5 mm amplitude
8 to 200 Hz: 2 g
200 to 500 Hz: 4 g
2 to 8 Hz: 7.5 mm amplitude
8 to 200 Hz: 2 g
200 to 500 Hz: 4 g
Table 11: Vibration
1)
Testing is performed per EN 60068-2-6.
2)
The specification refers to a device in its original packaging.
2.2.3.4 Shock
The following table provides an overview of the maximum shock values of the complete system. Limitations are
possible due to individual components.
Automation PC
Operation
1)
Storage
1)2)
Transport
1)2)
With CFast card
15 g, 11 ms
30 g, 6 ms
30 g, 6 ms
Table 12: Shock
1)
Testing is performed per EN 60068-2-27.
2)
The specification refers to a device in its original packaging.
2.2.3.5 Degree of protection
Under the following conditions, the Automation PC 3100 offers IP20 protection per EN 60529:
•
Correct installation of the Automation PC 3100 (see
)
•
Installation of all covers or components on interfaces and slots
•
Compliance with all ambient conditions