Software
Automation PC 3100 User's manual V 1.00
Translation of the original documentation
181
4.3.1 Legacy RAID
4.3.1.1 Configuring a SATA RAID volume using the internal RAID controller
The following software description applies to the internal RAID controller on
Kabylake-U
chipset.
Information:
B&R recommends using only the same drive type in the SATA RAID volume.
Caution!
The maximum number of possible write cycles must be taken into consideration when setting up a
RAID volume with CFast cards with MLC technology.
The "Configuration utility" in BIOS must be started after the reboot for the configuration. After POST, press <Ctrl
+I> to open the RAID BIOS.
Information:
Since the associated driver is not yet loaded at this point, touch screen input is not possible in the
"Configuration utility".
Information:
Input in the RAID menu are always processed according to the QWERTY schema. This is also the case
if a QWERTZ USB input device is connected.
Intel(R) Rapid Storage Technology - Option ROM - 15.7.0.3054
Copyright(C) Intel Corporation. All Rights Reserved.
RAID Volumes:
ID Name Level Strip Size Status Bootable
0 Mirror RAID1(Mirror) N/A 59.6GB
Yes
Normal
Physical Devices:
ID Device Model Serial # Size Type/Status(Vol ID)
0 SFCA064GH1AD4TO- 60143158A6000044 59.6GB
Member Disk(0)
1 SFCA064GH1AD4TO- 60143158A6000058 59.6GB
Member Disk(0)
Press <CTRL-I> to enter Configuration Utility..
Figure 52: RAID boot
StockCheck.com