Software
200
Automation PC 3100 User's manual V 1.00
Translation of the original documentation
4.9 B&R Automation Device Interface (ADI) Control Center
The Automation Device Interface (ADI) allows access to specific functions of B&R devices. The settings of these
devices can be read out and changed in Windows using the B&R Control Center in the Control Panel.
Figure 65: ADI Control Center screenshots - Examples
Information:
The displayed temperature and voltage values (e.g. CPU temperature, core voltage, battery voltage)
represent uncalibrated information values. No conclusions about possible alarms or hardware mal-
functions can be drawn from this. The hardware components used have automatic diagnostic func-
tions in the event of error.
4.9.1 Functions
Information:
The functions available in the Control Center depend on the device family.
•
Changing display-specific parameters
•
Reading out device-specific keys
•
Updating the key configuration
•
Enabling keys or device-specific LEDs of a membrane keypad
•
Reading out or calibrating control devices (e.g. key switch, handwheel, joystick, potentiometer)
•
Reading out temperatures, fan speeds, statistical data and switch positions
•
Reading out operating hours (power-on hours)
•
Reading user settings and factory settings
•
Reading software versions
•
Updating and backing up BIOS and firmware
•
Creating reports about the current system (support assistance)